Anniversary Sale — Make Your Ideas Stand Out. Grab your discount.

Rack PDU — Power Distribution Units

Basic, Metered, Smart and STS units for data-center racks, network cabinets and control rooms. Send us your rack layout and we will quote.

Choose your PDU type

Four lines, from plain power strips to per-outlet remote switching.

Basic PDU

Basic PDU

Straightforward power distribution

Metering
—
Outlets
UK · Schuko · NEMA · C13 / C19
Phase / current
1P / 3P · HVDC
Mounting
1U / 1.5U · 0U
Details →
Metered PDU

Metered PDU

See what each rack actually draws

Metering
V · A · kW · Hz · PF · kWh
Accuracy
±1%
Display
LCD
Communication
RS485 Modbus-RTU
Details →
Smart PDU

Smart PDU

Per-outlet visibility and remote control

Metering
Per outlet
Outlet control
Per outlet
Communication
LAN · RS485 · SNMP · MQTT
Series
A / B / C / D
Details →
STS / ATS

STS / ATS

Dual-feed redundancy for critical loads

Input sources
2 × AC
Transfer time
< 6 ms / < 11 ms
Phase / current
10 / 16 / 32 A · 1Φ+N+PE
Communication
SNMP (optional)
Details →

Basic PDU

Straightforward power distribution

Distributes power to server, network and control cabinets with no metering electronics in the way. Extruded aluminium chassis with a black powder coat and a solid copper busbar, so one failed outlet does not take the rest of the strip down. Horizontal or vertical mounting, with surge protection, breakers, fuses and USB / Type-C modules available on request.

Key advantages

  • Continuous copper busbar — a failed outlet does not cut the others
  • Mixed socket standards on one chassis: UK, Schuko, NEMA, IEC C13 / C19
  • Optional 10–40 kA surge modules, breakers and fuses
  • Single-phase AC, three-phase AC and 240 V / 336 V HVDC versions
Basic PDU
Metering
—
Outlets
UK · Schuko · NEMA · C13 / C19
Phase / current
1P / 3P · HVDC
Mounting
1U / 1.5U · 0U

Metered PDU

See what each rack actually draws

The same chassis with measurement built in. An LCD on the unit shows voltage, current, active power, frequency, power factor and accumulated energy, so racks can be loaded to their real limit instead of a guess. RS485 (Modbus-RTU) feeds the same figures to your monitoring system, and the meter module is hot-swappable — it can be replaced without dropping power to the outlets.

Key advantages

  • Local LCD readout: V, A, kW, Hz, PF and kWh
  • ±1% accuracy on voltage, current, power and energy
  • RS485 Modbus-RTU into your DCIM or BMS
  • Hot-swappable meter — no downtime to service it
Metered PDU
Metering
V · A · kW · Hz · PF · kWh
Accuracy
±1%
Display
LCD
Communication
RS485 Modbus-RTU

Smart PDU

Per-outlet visibility and remote control

Measures and switches every outlet individually. A flush-mounted controller (1 × LAN, 2 × RS485, 1 × temperature/humidity) handles local and remote management and hot-swaps out without powering down the rack. Four series — A, B, C and D — let you pay only for the level of metering and control you actually need.

Key advantages

  • Per-outlet metering and remote on/off switching
  • Alarm thresholds per branch for early warning
  • SNMP v1/v2c/v3, Modbus TCP/RTU, MQTT, SSHv2, HTTPS, IPv6
  • Daisy-chain with metered units to save ports and cost
Smart PDU

Smart iPDU — A / B / C / D series

FeatureABCD
Full-circuit metering
Per-phase metering
Per-outlet metering——
Per-outlet control——
Trip monitoring
Temp / humidity sensor

All four series include full-circuit and per-phase metering, ±1% accuracy, a temperature/humidity sensor, LCD, dual RS485 (Modbus) and 10/100 Ethernet. They differ only in per-outlet metering and per-outlet control.

Supported protocols

  • SNMP v1/v2c/v3
  • Modbus TCP/RTU
  • MQTT / MQTTS
  • HTTP / HTTPS
  • SSHv2
  • IPv4 / IPv6
  • DHCP
  • DNS
  • NTP
  • Syslog
  • SMTP / SMTPS
  • TLS v1.2

STS / ATS

Dual-feed redundancy for critical loads

A single-pole transfer switch sitting between two independent AC feeds. If one source drifts out of tolerance or fails, the load moves to the other one fast enough that connected equipment never sees an interruption. Fully digital DSP control with redundant auxiliary supplies, and an optional SNMP card for remote monitoring.

Key advantages

  • Two-stage transfer: < 6 ms typical, < 11 ms maximum
  • Fully digital DSP control with redundant auxiliary power
  • 10 A, 16 A and 32 A capacities, 1Φ + N + PE
  • Optional SNMP card for remote management
STS / ATS

Technical specifications

Input sources
2
Input configuration
1Φ + N + PE
Rated voltage
220 / 230 VAC
Rated frequency
50 / 60 Hz
Voltage range
150 – 300 VAC
Overload capacity
125% · 30 min
Efficiency (100% linear load)
98% – 99%
Transfer time
< 6 ms typ. · < 11 ms max.

Every unit is built to order — enclosure size, colour, socket mix and protection modules are all configurable.

PDU Enquiry

Send your rack layout, socket mix and current rating — our engineers will come back with a quote.

Pack everything into a single zip or rar archive, up to 100 MB.

Please sign in to submit your order.